LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> A985GOT-TBA-V
MITSUBISHI A985GOT-TBA-V Operating Manual A985GOT-TBA-V SW4D5C-GOTR-PACKE compatible Extended/Option Functions Manual Manual
Product model: A985GOT-TBA-V
Name: touch screen
Brand: MITSUBISHI
Sort: SW4D5C-GOTR-PACKE compatible Extended/Option Functions Manual Operating Manual
File language: English
Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 0.2ms below, below 1.5ms, 5ms below, 10ms the following.
Rated input voltage / current: DC12V/11mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No A985GOT-TBA-V Operating Manual.
Rated load voltage / current: DC12V/0.5A.
External connection: 3 line /2 line type A985GOT-TBA-V
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A985GOT-TBA-V Operating Manual. Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 12 points.
Output voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output response time: 0.5Hz+1ms.
Output type: bidirectional thyristor output.
8 point /1 a public end, 4 points / a public end A985GOT-TBA-V Operating Manual.
36 point terminal station.
With short circuit protection.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission devicce, brake signal and fan fault signal A985GOT-TBA-V Manual.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A985GOT-TBA-V Manual.
Related products
MITSUBISHI
12 inch man machine interface
A985GOT-TBA-EU
MITSUBISHI 12 inch man machine interface A985GOT-TBA-EU
Series Name: A985GOT. Size: 12 inches. R
MITSUBISHI
12 inch man machine interface
A985GOT-TBA
MITSUBISHI 12 inch man machine interface A985GOT-TBA
Series Name: A985GOT. Size: 12 inches. R
MITSUBISHI
12 inch man machine interface
A985GOT-TBA-V
MITSUBISHI 12 inch man machine interface A985GOT-TBA-V
Series Name: A985GOT-V. Size: 12 inches.
MITSUBISHI
12 inch man machine interface
A985GOT-TBD-V
MITSUBISHI 12 inch man machine interface A985GOT-TBD-V
Series Name: A985GOT-V. Size: 12 inches.