Manual Download >> A953GOT-LBD-M3
MITSUBISHI A953GOT-LBD-M3 Manual A953GOT-LBD-M3 Connection System Manual User's Manual
Product model: A953GOT-LBD-M3
Name: touch screen
Brand: MITSUBISHI
Sort: Connection System Manual User's Manual
File language: English
Input type: DC input, negative public end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, source.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0 A953GOT-LBD-M3 User's Manual. 1A.
External connection: 3 line /2 line type.
Sensor connector type (E-CON type) A953GOT-LBD-M3
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Cable length 1m; used in A6TE2-16SRN.Output points: 16 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink) A953GOT-LBD-M3 User's Manual.
Response time: 2ms.
8 points / a common end.
20 point terminal station.
With heat protection.
With short circuit protection.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read A953GOT-LBD-M3 User's Manual.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requuirements,
Should consider the best performance to price ratio, a reasonable choice of PLC A953GOT-LBD-M3 Manual.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A953GOT-LBD-M3 Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.