MITSUBISHI A64RD3C Manual A64RD3C User's Manual
Product model: A64RD3C
Name: Pt100 input module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/ all points.
Output type: relay output.
Response time: 12ms.
All points of independence.
38 point terminal station.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor A64RD3C User's Manual A64RD3C
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc A64RD3C User's Manual. .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A64RD3C User's Manual.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. Remote I/O controller, optical fiber GI.
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc..
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps.
Design PLCC peripheral hardware circuit A64RD3C Manual .
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system compoosed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram A64RD3C Manual .
So far the system''s hardware electrical circuit has been determined.
Related products
MITSUBISHI
Temperature input module (RTD)
A64RD3C
MITSUBISHI Temperature input module (RTD) A64RD3C
4 channels. 3 wire type. Platinum resist
MITSUBISHI
Analog output module
A64DAVC
MITSUBISHI Analog output module A64DAVC
4 channels. Input: DC0 20mA. Output r
MITSUBISHI
Interface unit of ultrasonic linear meter
A64BTL
MITSUBISHI Interface unit of ultrasonic linear meter A64BTL
4 channels. Measurement range: 0.000-355
MITSUBISHI
Analog output module
A64DAIC
MITSUBISHI Analog output module A64DAIC
4 channels. Input resolution: -4000