LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> A2ACPU-S1
MITSUBISHI A2ACPU-S1 Manual A2ACPU-S1 Hardware User's Manual
Product model: A2ACPU-S1
Name: PLC
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
DC input points: 8 points.
Input voltage and current: 7mA, DC24V.
Response time: 10ms.
8 point /1 a public side.
Positive / negative sharing.
Output points: 8 points.
Output voltage and current: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Response time: 12ms.
8 point /1 a public side.
Output form: relay output A2ACPU-S1 User's Manual.
34 point terminal station.
Number of stations: 2 stops.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program A2ACPU-S1
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system A2ACPU-S1 User's Manual.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong A2ACPU-S1 User's Manual.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. Data communication line module (optical cable) Master / local station for A3VTS multiplex system
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations. Enter 32 points.
5mA DC24V.
Response time: 0.3ms.
32 point 1 public.
Output 32 points.
DC12/24V.
Leakage current: 0.1mA OFF.
Response time: 1ms. 32 point 1 public.
Protection function.
Surge.
40 pin connector.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combinatiion of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order A2ACPU-S1 Manual .
So, sometimes also known as the order control.
And seqquential control is divided into manual, semi-automatic or automatic A2ACPU-S1 Manual .
And the control principle is decentralized, centralized and hybrid control three.
Related products
MITSUBISHI
CPU unit
Q2ASHCPU-S1
MITSUBISHI CPU unit Q2ASHCPU-S1
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A2ACPU
MITSUBISHI CPU unit A2ACPU
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
A2ACPUP21-S4
MITSUBISHI CPU unit A2ACPUP21-S4
Input and output points: 1024 points. In