LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> A1SY40P
MITSUBISHI A1SY40P Manual A1SY40P User's Manual
Product model: A1SY40P
Name: I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
A pack of 5.
Applicable models:
AJ65VBTS - - - type.
AJ65VBTCE - - - type.
AJ65VBTCU - - - type.
AJ65ABTP - - - type.
AJ65VBCU- - type.
AJ65SBT-CLB type. RS-422 connection (QnA/A/FXCPU direct connection, computer connection, micro computer connection).
No clock function.
Applicable model: A956WGOT. Input voltage range: DC110/125V A1SY40P User's Manual.
Output voltage: DC5V.
Output current: 8A.
For Q4ARCPU A1SY40P
The control module monitors the power supply, the error
CPU state,
And its own error state.
It sends out
Error signal a6raf and open the corresponding
Relay output.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest A1SY40P User's Manual.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30% A1SY40P User's Manual.
The following describes the centralized control system I/O points of the estimate. Input and output points: 256 points.
Input / output data points: 256 points.
Program capacity: 6k.
Basic command processing speed (LD command) s:1.0.
Internal storage RAM memory capacity: 16k.
Optical data communication line function with power supply.
Input / output data control mode conversion.
It is possible to enter the control of the output data as the following 3.
(1) input: direct mode, output: direct mode.
(2) input: I/O impression update mode, output: direct mode.
(3) input: I/O impression update mode, output: I/O impression update mode.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions ffor 2~4 A1SY40P Manual.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure A1SY40P Manual.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Related products
MITSUBISHI
Melsecnet interface module
A1SJ71AR21
MITSUBISHI Melsecnet interface module A1SJ71AR21
PLC station distance: 500M. Cale type:
MITSUBISHI
floor
A1S38HB
MITSUBISHI floor A1S38HB
8 slots. Power supply unit. QnAS series
MITSUBISHI
Positioning control module
A1SD75M3
MITSUBISHI Positioning control module A1SD75M3
Axis of control: 3 axis linkage, 3 axis
MITSUBISHI
Conversion module
FA-TBS40P
MITSUBISHI Conversion module FA-TBS40P
Converts the uilt-in I/O function to th