LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> A1SCPUC24-R2
MITSUBISHI A1SCPUC24-R2 Programming Manual PLC Fundamentals Manual
Product model: A1SCPUC24-R2
Name: PLC
Brand: MITSUBISHI
Sort: Fundamentals Programming Manual
File language: English
MELSECNET/10, MELSECNET/H coaxial.
Input voltage: DC24V.
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc..
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps A1SCPUC24-R2 Manual A1SCPUC24-R2
Design PLC peripheral hardware circuit.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system composed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram A1SCPUC24-R2 Manual .
So far the system''s hardware electrical circuit has been determined. Multi axis positioning controller.
Program capacity: Max 60K step.
Input / output points: 1920 points.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of A1SCPUC24-R2 Manual .
The photoelectric coupler is composed of two luminous two extreme tubes and a photoelectric transistor MITSUBISHI PLC Manual .
Light emitting diode two: the input of a photo coupler and the change of electrical signal,
The light signal is generated by the light emitting diode, which is the same as the input signal MITSUBISHI PLC Manual .
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light MITSUBISHI PLC Manual .
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal.
Photoelectric three levels: in the light of the light signal conduction, the degree of light signal and the intensity of the light signal.
The output signal has a linear relationship with the input signal in the linear operating region of the photoelectric coupler.
User program storage capacity: it is a measuure of how much the user application can store the number of indicators A1SCPUC24-R2 Programming Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words A1SCPUC24-R2 Manual . Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
Serial communication module
RJ71C24-R2
MITSUBISHI Serial communication module RJ71C24-R2
230.4kps Max., RS-232 2 channel. When u
MITSUBISHI
Serial communication module
QJ71C24-R2
MITSUBISHI Serial communication module QJ71C24-R2
"2CH RS-232. QJ71C24N -R2 through the
MITSUBISHI
Serial communication module
A1SJ71QC24-R2
MITSUBISHI Serial communication module A1SJ71QC24-R2
RS-232 2 channel. Transfer speed: 0.3-19
MITSUBISHI
CPU unit
A1SCPU
MITSUBISHI CPU unit A1SCPU
Program memory capacity: 8k. Input / out