LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> A1S62TCRTBW-S2 
MITSUBISHI A1S62TCRTBW-S2  User's Manual Heating-Cooling Temperature Control Module Manual
Product model: A1S62TCRTBW-S2 
Name: Heating-Cooling Temperature Control Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
A pack of 10.
Applicable models:
AJ65VBTCE - -8 - type.
AJ65VBTCE - -16 - type. 2 channels.
Input: DC-10 ~ 10V, DC4 ~ 20mA.
Output (resolution): -2000 ~ 2000, -1000 ~ 1000.
Transform speed: 15ms/2 channel.
20 point terminal station.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register A1S62TCRTBW-S2  Manual A1S62TCRTBW-S2 
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive A1S62TCRTBW-S2  Manual .
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light A1S62TCRTBW-S2  Manual .
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal MITSUBISHI Heating-Cooling Temperature Control Module Manual MITSUBISHI Heating-Cooling Temperature Control Module Manual .
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process MITSUBISHI Heating-Cooling Temperature Control Module Manual . RS-422 1 channel, RS-422/485 1 channel.
Transmission speed: 2 channel total is 115.2kbps.
Control layer /MELSECNET/10 (H) is the middle layer of the whole network system,
Control network which is convenient and high speed processing data transmission between PLC, CNC and other control equipment.
As MELSEC control network MELSECNET/10,
With its good real-time performance, simple network settings, no procedures of the network data sharing conncept,
As well as the redundant circuit and so on, has obtained the very high market appraisal,
The number of devices to reach the highest in japan,
In the world is also one of the few A1S62TCRTBW-S2  User's Manual.
And MELSECNET/H not only inheritedd the excellent characteristics of MELSECNET/10,
Also makes the network real-time better, more data capacity,
Further adapt to the needs of the market A1S62TCRTBW-S2  Manual .
Related products
MITSUBISHI
Temperature control module
A1S62TCRTBW-S2
MITSUBISHI Temperature control module A1S62TCRTBW-S2
Numer of channels: 2 channels. Sensing