LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> A161
MITSUBISHI A161 Manual A161 User's Manual
Product model: A161
Name: Interruption input Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
For common cathode input module (3 line type).Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 wire.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring A161 User's Manual.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module A161
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring. Cable length: 3 meters.
For QnA/A/FX (FX1, FX2, FX2C) CPU and GOT connection between A161 User's Manual.
For connection between FA-CNV_CBL and GOT.
For connection between FX-2PIF and GOT.
For connection between FX-422AW0 and GOT.
For serial communication module AJ71QC24 (N) -R4 and GOT connection between.
For connection between AJ65BT-G4-S3 and GOT. Input and output points: 256 points.
Input / output data points: 256 points.
Program capacity: 6k.
Basic command processing speed (LD command) s:1 A161 User's Manual. 0.
Internal storage RAM memory capacity: 16k.
Optical data communication line function with power supply.
Input / output data control mode conversion.
It is possible to enter the control of the output data as the following 3.
(1) input: direct mode, output: direct mode.
(2) input: I/O impression update mode, output: direct mode.
(3) input: I/O impression update mode, output: I/O impression update mode.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructionss for 2~4 A161 Manual .
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure A161 Manual .
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Related products
MITSUBISHI
Melsecnet interface module
A1SJ71AP21
MITSUBISHI Melsecnet interface module A1SJ71AP21
PLC station distance: 1Km. Cale type: Q
MITSUBISHI
High speed counting module
A1SD62DE
MITSUBISHI High speed counting module A1SD62DE
Numer of channels: 2 channels. Input si
MITSUBISHI
Temperature control module
A1S64TCRTBW-S1
MITSUBISHI Temperature control module A1S64TCRTBW-S1
Numer of channels: 4 channels Sensing m
MITSUBISHI
Extension cable
A1SC03B
MITSUBISHI Extension cable A1SC03B
Cale length: 0.33 meters. Extending ca