LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> A0j2-E56AS
MITSUBISHI A0j2-E56AS Manual A0j2-E56AS User's Manual
Product model: A0j2-E56AS
Name: Input/Output Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
SI-200/250 fiber optic cable.
Double loop.
MELSECNET (II) (Master / local station).
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc..
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps A0j2-E56AS User's Manual A0j2-E56AS
Design PLC peripheral hardware circuit.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system composed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram A0j2-E56AS User's Manual.
So far the system''s hardware electrical circuit has been determined. 8 channel analog output module.
Ans series has now launched a dedicated 8 channel D/A components,
Both voltage output and current output can be provided.
In this way, the user system to provide a higher density of D/A features,
The same method is used to maintain the same output voltage or current output A0j2-E56AS User's Manual. Output type: transistor source.
Output points: 16 points.
Load voltage: DC5/12/24.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 8.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three. Input and output points: 1024 points.
Input / output data points: 1024 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a meeasure of how much the user application can store the number of indicators A0j2-E56AS Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words A0j2-E56AS Manual. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
Connecting cable
A0J2-C04B
MITSUBISHI Connecting cable A0J2-C04B
A65B/A68B/A55B/A58B connection cale. Le
MITSUBISHI
Connecting cable
A0J2-C06
MITSUBISHI Connecting cable A0J2-C06
Horizontally placed cale. Length: 550mm
MITSUBISHI
Connecting cable
A0J2-C03
MITSUBISHI Connecting cable A0J2-C03
Horizontally placed cale. Length: 300mm
MITSUBISHI
DC input / relay output module
A0J2-E28DR
MITSUBISHI DC input / relay output module A0J2-E28DR
Input points: 16 points. Input voltage a