Slim type non isolated.
Input power: DC24V.
Output: DC5V, 5A.
Power supply module can be directly pasted on the printed circuit board of the power supply,
The device is characterized in that a special integrated circuit (ASIC), a digital signal processor (DSP), a microprocessor, a memory, a field programmable gate array (FPGA), and other digital or analog loads are provided MITSUBISHI LM-H2 Manual LM-H2
In general, this type of module is called the load point (POL) power supply system or the use of point power supply system (PUPS).
Because of the advantages of the modular structure,
The module power supply is widely used in switching devices, access devices, mobile communications, microwave communications and optical transmission, routers and other communication fields and automotive electronics, aerospace, etc MITSUBISHI LM-H2 Manual. . "Thermocouple input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode MITSUBISHI LM-H2 Manual.
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used ffor the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling LM-H2 INSTRUCTION MANUAL.
According to the object device can choose any one of the following control method.
Standard controol (heating or cooling) LM-H2 INSTRUCTION MANUAL.
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control).
Related products
MITSUBISHI
Resist film
GT16-60PSGW
MITSUBISHI Resist film GT16-60PSGW
Protective film for 8.4 inch screen. Scr
MITSUBISHI
AC reactor
FR-HAL-H22K
MITSUBISHI AC reactor FR-HAL-H22K
Power: 22kw. Purpose: to suppress the po
MITSUBISHI
Q bus connecting cable
A9GT-QC350BS
MITSUBISHI Q bus connecting cable A9GT-QC350BS
Cale length: 35 meters. For QCPU and GO
MITSUBISHI
Resist film
GT11-50PSCB
MITSUBISHI Resist film GT11-50PSCB
Protective film for 5.7 inch screen. Tra