L26CPU-CM Manual MITSUBISHI L26CPU-CM Structured Text Programming Manual
Product model: L26CPU-CM
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text Programming Manual
File language: English
Control axis: maximum 4 axes.
Operation cycle: 0.88ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points.
Color detecting set: 4 set.
Only need to use the PLC program can easily achieve synchronous control, cam control, speed and torque (push pressure control) and other advanced motion control MITSUBISHI L26CPU-CM Programming Manual.
Equipped with standard synchronous encoder and color detection function necessary function L26CPU-CM
Can be no procedures for setting. Strong support for MELSOFT.
Can fully apply LD77MH of the old program.
Let motion control more simple. Number of input channels: 4ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 20 s/ch MITSUBISHI L26CPU-CM Programming Manual.
Resolution: 1/20000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range MITSUBISHI L26CPU-CM Programming Manual.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter range extension
Range of scalable input range.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected. Number of input channels: 4ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 40 s/2ch.
Resolution: 1/32000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuouus analog output L26CPU-CM Manual .
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period L26CPU-CM Manual .
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.
Related products
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type.
MITSUBISHI
cpu module
L02SCPU-CM
MITSUBISHI cpu module L02SCPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L26CPU-BT-CM
MITSUBISHI cpu module L26CPU-BT-CM
"Universal output function: leakage type