Input and output points: 10 points.
Power supply: DC24V.
Input points: 6 points.
Output points: 4 points.
Output form: transistor output (source).
Power consumption: 6W.
Weight: 0.22KG.
Outline dimension: 60x90x49mm.
Built in CPU, power supply, input and output.
Keep FX1S compact body, while adding more features FR-A7AR Manual .
Special adaptor and function expansion board can be installed and used FX3 series
FR-A7AR
High speed operation.
Basic instructions: 0.21 s/ instruction
Application instruction: 0.5 s/ instruction
Large capacity memory.
Built in program memory 4000 steps.
No battery.
Auxiliary relay: 1536 points.
Timer: 138 points.
Counter: 67.
Data register: 3000.
A new application model.
FX3SA is a basic model on the basis of the basic performance of the FX1S increased the expansion of the new models FR-A7AR Manual .
FX3SA is suitable for all kinds of fields, such as analog quantity, Ethernet, MODBUS function, small scale equipment and so on.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and the communication function and so on. Can be isolated to obtain DC24/48/100V, AC100/200V input signal FR-A7AR Manual . Connecting cable for handheld GOT and PLC.
Cable length: 3 meters.
Application: RS-422 connection. Input signal power: 40mA. DC24V
Axis of control: 1.
Output frequency: Max 200kHz.
Weight: 0.2kg.
FX3U-1PG is a pulse output module of the maximum output 200kHz pulse train MITSUBISHI FR-A7AR Instruction manual.
7 operation modes needed to take the simple position control.
The speed and the target address can be changed in the positioning operation according to the operation of the project,
Support near S shape plus deceleration MITSUBISHI FR-A7AR Instruction manual. High speed positioning can be carried out smoothly.
Up to 8 units can be connected to FX3U or FX3UC.
Connecting FX3UC requires FX2NC-CNV-IF or FX3UC-IPS-5V. Power: 11kw MITSUBISHI FR-A7AR Instruction manual.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resisstor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling FR-A7AR Relay output function.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between thhe short circuit chip, in addition to connecting the DC reactor FR-A7AR Manual .
The installation of thermal relay, to avoid overheating and burn the braking resistor.