LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> G3J-S403BL
G3J-S403BL INSTRUCTION MANUAL OMRON G3J-S403BL Manual
Product model: G3J-S403BL
Name: solid-state contactor
Brand: OMRON
Sort: INSTRUCTION MANUAL
File language: English
Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 35 A, 100 to 240 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications OMRON G3J-S403BL Manual.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents G3J-S403BL (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Name: Slice I/O Units; Temperature Input.
(Resistance Thermometers).
Specifications: Temperature input,
(Resistance thermometer:Pt100) 2 points OMRON G3J-S403BL Manual.
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON G3J-S403BL Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Internal I/O common: PNP.
I/O indicators: LED display (yellow).
Unit power supply current consumption:
80 mA max. (for 20.4 to 26.4-VDC power supply voltage)
Weight: 190 g max.
Expansion functions: No.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unit per one I/O terminal unit.)
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance. High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 ccommunications to set manipulated variables and,
monitor load current G3J-S403BL INSTRUCTION MANUAL.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G3J-S403BL INSTRUCTION MANUAL.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.
Related products