FX3U SERIES Manual MITSUBISHI PLC FX3U SERIES HARDWARE MANUAL
Product model: FX3U SERIES
Name: PLC
Brand: MITSUBISHI
Sort: HARDWARE MANUAL
File language: English
Power: 55kw.
Voltage: 200V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. Voltage input: DC0~10V, DC0~5V.
Current input: DC4~20mA.
Voltage output: DC0~10V, DC0~5V MITSUBISHI PLC HARDWARE MANUAL.
Current output: DC4~20mA.
Applicable PLC:FX1N, FX2N, FX1NC, FX2NC (to FX2NC-CNV-IF) FX3U SERIES
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
8 bit binary resolution analog input and output modules.
Input output mixed module with 2 channel analog input and 1 channel analog output.
Voltage input and current input of 2 channels can be carried out.
1 channel analog output can be the output voltage or current output MITSUBISHI PLC HARDWARE MANUAL. Power: 280kw.
Voltage: 400V.
Purpose: high frequency braking resistor.
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor.
Can also be connected without built-in brake transistor inverter.
Three types of discharge resistors are available.
Please select according to the required braking torque MITSUBISHI PLC HARDWARE MANUAL. Can be used as a screw relay terminal.Power: 18.5kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity FX3U SERIES HARDWARE MANUAL.
At the same time the installation options in the use of 75kW and above motor FX3U SERIES HARDWARE MANUAL. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Input and output points: 32 points.
Input points: 16 points.
Input specifications: drain / source FX3U SERIES HARDWARE MANUAL.
Output points: 16 points.
Output form: transistor output (source).
Power consumption: 8W.
Weight: 0.2KG.
Outline dimension: 34x90x87mm.
Hard and compact type third generation micro programmable controller.
Connector type input and output type provincial connection.
Greatly strengthened the industry''s highest level of high-speed processing and positioning and other built-in features.
High cost of the province space models.
FX3UC in the province of space, the province also greatly strengthened the connection of high-speed processing and positioning and other built-in features.
The host is built in DC24V power supply, the connector input and output form of the transistor output.
In addition, accordinng to the product mix can also achieve network communications, analog control, data collection and other functions FX3U SERIES Manual.
Third generation high function micro programmable controller.
Connector type can save space, province wiring MITSUBISHI PLC HARDWARE MANUAL.
Built in high speed processing and positioning.
Ultra small size, control points to 256 points.
Construction of CC-Link remote I/O 384 points.
Related products
MITSUBISHI
A mode Q series CPU
Q02HCPU-A
MITSUBISHI A mode Q series CPU Q02HCPU-A
Input / output points: 4096 points. Num
MITSUBISHI
Safety CPU
R16SFCPU-SET
MITSUBISHI Safety CPU R16SFCPU-SET
Safety grade SIL: SIL 3 IEC 61508. P
MITSUBISHI
Large CPU expansion cable
GT15-C30NB
MITSUBISHI Large CPU expansion cable GT15-C30NB
Cale length: 3.0m. For QnA/ACPU/ motion