FX3U-64MT/ES-A Manual MITSUBISHI PLC FX3U-64MT/ES-A Positioning Control Edition USER'S MANUAL
Product model: FX3U-64MT/ES-A
Name: PLC
Brand: MITSUBISHI
Sort: Positioning Control Edition USER'S MANUAL
File language: English
Voltage level: three phase 400V.
Applicable motor capacity: 315kw.
Substrate coating: have.
Built in DC reactor.
The operating frequency of the fixed alternating current is converted to DC power. Function extension board for RS-232C communication.
DC5V power consumption: 20mA. Input points: 8 points MITSUBISHI PLC USER'S MANUAL.
Output points: 6 points.
Power supply voltage: AC100-240V.
Output type: transistor output (drain) FX3U-64MT/ES-A
A free combination of PLC.
FX3G basic unit: 14/24/40/60 point.
FX3GA is a compact PLC, simple design and with the basic functions of the FX3 series.
Through the strengthening of the built-in function and flexible expansion, expanded in various fields of application.
Third generation standard model MITSUBISHI PLC USER'S MANUAL.
High flexibility.
Suitable for small scale control of high cost.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function. MITSUBISHI inverter series: FR-F840 MITSUBISHI PLC USER'S MANUAL.
Voltage level: three phase 400V.
Power: 2.2kw.
SLD converter rated current: 5.2A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed FX3U-64MT/ES-A USER'S MANUAL.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption FX3U-64MT/ES-A USER'S MANUAL.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control FX3U-64MT/ES-A USER'S MANUAL. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 1.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Bassically can not be used FX3U-64MT/ES-A Manual. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced MITSUBISHI PLC USER'S MANUAL.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.
Related products
MITSUBISHI
PLC
FX3U-64MT/DS
MITSUBISHI PLC FX3U-64MT/DS
Max input / output points: 64 points. Po
MITSUBISHI
PLC
FX3U-16MT/ES-A
MITSUBISHI PLC FX3U-16MT/ES-A
Max input / output points: 16 points. Su
MITSUBISHI
PLC
FX3G-60MT/ES-A
MITSUBISHI PLC FX3G-60MT/ES-A
Input points: 36 points. Output points:
MITSUBISHI
PLC
FX3U-64MT/ES-A
MITSUBISHI PLC FX3U-64MT/ES-A
Max input / output points: 64 points. Su