FX3U-2HSY-ADP Manual MITSUBISHI Line Driver Output FX3U-2HSY-ADP Positioning Control Edition USER'S MANUAL
Product model: FX3U-2HSY-ADP
Name: Line Driver Output
Brand: MITSUBISHI
Sort: Positioning Control Edition USER'S MANUAL
File language: English
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Total input and output points: 32 points.
Input points: 16 points.
Output points: 16 points.
Output type: transistor output.
Power supply voltage: AC100-240V.
Input signal voltage: DC24V.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter MITSUBISHI Line Driver Output USER'S MANUAL FX3U-2HSY-ADP
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Taking into account space saving and processing speed.
Connector input and output type compact high performance universal machine MITSUBISHI Line Driver Output USER'S MANUAL.
Compact, scalable input / output.
Can connect analog quantity, communication, positioning, etc..
Rich special extension equipment for FX2N.
By connecting the compact FX2rvc series with the input and output expansion module.
The input and output can be extended to 256 points.
Built in 8000 step RAM memory.
By installing the memory card box, the maximum can be extended to the 16000 step MITSUBISHI Line Driver Output USER'S MANUAL.
Overseas oriented products meet all kinds of international standards.
Use terminal module to replace connector connection or relay terminal row connection,
So as to save the wiring inside the cabinet FX3U-2HSY-ADP USER'S MANUAL.
Customers can according to their own needs, free choice of MITSUBISHI motor micro programmable controller FX series FX3U-2HSY-ADP USER'S MANUAL.
FX series can be widely used to control a variety of varied areas.
More convenient.
You can shorten the working hours of the development process by a minimal set of settings.
High reliability.
Excellent features, as always, quality and reliability.
MITSUBISHI motor to recommend the third generation of micro programmable controller FX3 series FX3U-2HSY-ADP USER'S MANUAL.
High function, high precision, high cost performance. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 37KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testiing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX3U-2HSY-ADP Manual.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter MITSUBISHI Line Driver Output USER'S MANUAL. "
Related products
MITSUBISHI
High speed counting module
FX3U-2HC
MITSUBISHI High speed counting module FX3U-2HC
Maximum frequency: 200kHz. Input points:
MITSUBISHI
RS-232C adapter
FX3U-232ADP
MITSUBISHI RS-232C adapter FX3U-232ADP
Adapter RS-232 communication FX3U- - ra
MITSUBISHI
Modular
FX3U-20SSC-H
MITSUBISHI Modular FX3U-20SSC-H
Auxiliary parts for FX3GC and FX3UC. "
MITSUBISHI
Adapter for high speed output
FX3U-2HSY-ADP
MITSUBISHI Adapter for high speed output FX3U-2HSY-ADP
High speed output adapter FX3U- - racy