Input and output points: 60 points.
Power supply: AC100-240V.
Input points: 36 points.
Output points: 24 points.
Output form: transistor output (drain).
Power consumption: 40W.
Weight: 0.85KG.
Outline dimension: 175x90x86mm.
EEPROM memory cartridge with program transfer function.
Third generation standard model MITSUBISHI FX2NC-232ADP Manual.
Easy to use integrated models and flexible scalability
FX2NC-232ADP
Condensed convenience of using the usual FX3 series.
Its high price by the most suitable for small scale control.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
Auxiliary relay: 7680 points.
Timer: 320 points MITSUBISHI FX2NC-232ADP Manual.
Counter: 235.
Data register: 8000.
Extended register: 24000 point.
Extended file register: 24000.
A free combination of PLC.
FX3G basic unit: 14/24/40/60 point.
FX3GA is a compact PLC, simple design and with the basic functions of the FX3 series.
Through the strengthening of the built-in function and flexible expansion, expanded in various fields of application.
Third generation standard model MITSUBISHI FX2NC-232ADP Manual.
High flexibility.
Suitable for small scale control of high cost.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points. Max input / output points: 64 points.
Power supply voltage: 24VDC.
Input points: 32 points.
Output points: 32 points.
Output type: relay.
Power consumption: 35W.
Weight (kg):1.0.
Size (WxHxD) mm:220x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eightt digit password to protect your program FX2NC-232ADP INSTALLATION MANUAL.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FX2NC-232ADP INSTALLATION MANUAL.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).