Max input / output points: 48 points.
Supply voltage: 100 - 240VAC.
Input points: 24 points.
Output points: 24 points.
Output type: silicon controlled.
Power consumption: 50VA.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x87.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications MITSUBISHI FX2N-64MT-D Manual
FX2N-64MT-D
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K MITSUBISHI FX2N-64MT-D Manual.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable MITSUBISHI FX2N-64MT-D Manual.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online programPower: 18.5kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Convert connector to screw relay terminal.
The action of the signal of the conversion module is shown in the light of the lamp.
Positive common end display. Station type: intelligent equipment station.
Remote input / output: 128 points.
Remote register: 32.
Occupied points: 8 points.
Transfer speed: 10Mbpss FX2N-64MT-D PROGRAMMING MANUAL II.
Power supply: 240mA DC24V.
Weight: 0.3kg.
FX3U-64CCL can be connected to the FX-PLC as an intelligent device station.
In addition, through the connection of the various manufacturers of machinery, can be used to set up the system FX2N-64MT-D PROGRAMMING MANUAL II.
Can be connected to FX3GA, FX3GE, FX3GC, FX3U and FX3UC of the host.
Connecting FX3UC, FX3GC requires FX2NC-CNV-IF or FX3UC-IPS-5V.