Power: 3.7kw.
Voltage: 200V.
Purpose: high frequency braking resistor.
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor.
Can also be connected without built-in brake transistor inverter.
Three types of discharge resistors are available MITSUBISHI INVERTER INSTRUCTION MANUAL.
Please select according to the required braking torque. Input and output points: 24 points
FR-F720-00046 to 04750-NA
Power supply: AC100-240V.
Input points: 14 points.
Output points: 10 points.
Output form: transistor output (drain).
Power consumption: 32W.
Weight: 0.55KG.
Outline dimension: 90x90x86mm.
FX3GE on the performance of the FX3GA increased analog input / output and Ethernet communication and other built-in features MITSUBISHI INVERTER INSTRUCTION MANUAL.
Applicable to a wide variety of applications.
Basic unit: 24/40 point.
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost PLC.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
A versatile PLC.
Built in CPU, power supply, input and output, analog input and output, Ethernet port, can be used immediately after the purchase MITSUBISHI INVERTER INSTRUCTION MANUAL.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function. MITSUBISHI inverter series: FR-F840 FR-F720-00046 to 04750-NA INSTRUCTION MANUAL.
Voltage level: three phase 400V.
Power: 37kw.
SLD converter rated current: 77A FR-F720-00046 to 04750-NA INSTRUCTION MANUAL.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup.
No need to adjust the parameters (plus deceleration time or torque, etc FR-F720-00046 to 04750-NA INSTRUCTION MANUAL. ), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor.
In the sttate of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor) FR-F720-00046 to 04750-NA Manual.
Othher manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving MITSUBISHI INVERTER INSTRUCTION MANUAL.