MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 18.5kw.
SLD converter rated current: 93A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on MITSUBISHI FR-E540-0
FR-E540-0.4K-CH4K-CH TECHNICAL MANUAL.
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units MITSUBISHI FR-E540-0.4K-CH TECHNICAL MANUAL.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display. Can be used as a screw relay terminal.MITSUBISHI inverter series: FR-A800.
Voltage level: three phase 400V.
Power: 250kw.
SLD converter rated current: 610A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Mirror like ultra fine processing.
In order to adapt to the new material diversification, the machine adopts the most cutting-edge technology, more than ever more slim hard MITSUBISHI FR-E540-0.4K-CH TECHNICAL MANUAL.
In order to be able to realize the fine cutting, grinding on the hard and hard material,
The need for high-speed operation has become more and more strong.
In order to cope with the increasing demand of logistics, every port in the world has a crane in every day.
A container filled with cargo.
We can achieve a new type of inverter products under the conditions of low speed and high torque to achieve smooth cargo handling operations,
Carry on the smooth movement to the heavy. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 45KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, even if the load changess are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection) FR-E540-0.4K-CH Manual.
If the given acceleration time is too short, the output frequency of the inverter is far more than thhe change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall FR-E540-0.4K-CH Manual.