Power: 15kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. Voltage level: three phase 400V.
Applicable motor capacity: 500kw MITSUBISHI INVERTER Instruction manual.
Substrate coating: have.
Built in DC reactor.
The operating frequency of the fixed alternating current is converted to DC power
FR-D720-0.2K MITSUBISHI inverter FR-D720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 1.5KW.
Vector control variable frequency speed control is the practice of the asynchronous motor in the three-phase coordinate system of the stator current Ia, Ib, Ic, through the three-phase to two-phase transformation,
The alternating current of Ia1Ib1 is equivalent to a two phase stationary coordinate system, and then is rotated by the rotor field oriented,
Equivalent to the DC current Im1, It1 (Im1 equivalent to DC motor excitation current in synchronous rotating coordinate system;
It1 equal to the armature current proportional to the torque, and then imitate the DC motor control method, to obtain the DC motor control,
The control of asynchronous motor is realized through the corresponding inverse coordinate transformation MITSUBISHI INVERTER Instruction manual MITSUBISHI INVERTER Instruction manual. Input / output type: transistor output (source) FR-D720-0.2K Instruction manual.
Output points: 8 points.
DC5V internal consumption current: 75mA.
DC24V internal consumption current: 75mA.
In order to extend the input output of the device FR-D720-0.2K Instruction manual.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. MITSUBISHI inverter series: FR-F820 FR-D720-0.2K Instruction manual.
Voltage level: three phase 200V.
Power: 5.5kw.
SLD converter rated current: 34A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
(rectifier separation type will vary)
AAlso, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station FR-D720-0.2K Manual .
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same timme, used in the control of the external machine MITSUBISHI INVERTER Instruction manual.
No external PID controller is used to control the external machine, so the system cost can be reduced.