FR-A820-55K-1 Manual MITSUBISHI INVERTER FR-A820-55K-1 PLC FUNCTION Programming Manual
Product model: FR-A820-55K-1
Name: INVERTER
Brand: MITSUBISHI
Sort: PLC FUNCTION Programming Manual
File language: English
Function: input / output module (internal service power supply).
Input / output points: 32 points
Input points: 16 points.
Output points: 16 points.
DC5V internal consumption current: 965mA.
DC24V internal consumption current: 250mA.
Input / output mode: DC input (drain / source) / relay output.
In order to extend the input output of the device MITSUBISHI INVERTER Programming Manual.
Also has a built-in power supply products FR-A820-55K-1
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. Memory format: EEPROM.
Number of steps: up to 16000 steps can be used.
Battery support: do not MITSUBISHI INVERTER Programming Manual.
Method for writing and deleting: the device is installed on the PLC, and is written and deleted by the peripheral device.
Note: built-in extension. Special module for RS-232C communication.
This serial communication module, you can communicate with the computer, printer, code reader and other equipment with RS-232C communication function.
The data can be transmitted through the buffer storage area of the module, and the data transfer between the PLC host and the module is realized MITSUBISHI INVERTER Programming Manual.
When you connect to FX3UC, you need FX2NC-CNV-IF or FX3UC-1PS-5V. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V FR-A820-55K-1 Programming Manual.
Frequency converter capacity: 3.7KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) FR-A820-55K-1 Programming Manual.
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical FR-A820-55K-1 Programmingg Manual FR-A820-55K-1 Manual .
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the ttorque automatic enhancement function, the starting torque is more than 100%, which can start with full load MITSUBISHI INVERTER Programming Manual. Analog output expansion board (1 channel).