LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> GX-MD1618
EtherCAT Remote I/O Slaves GX-MD1618 Safety Precautions OMRON GX-MD1618 Manual
Product model: GX-MD1618
Name: EtherCAT Remote I/O Slaves
Brand: OMRON
Sort: Safety Precautions
File language: English
Name: Cycle Control Unit.
Isolation transformer: Yes.
Rated power supply voltage: 100 to 240 VAC.
Refer to Safety Precautions for All Power Controllers.
Used in Combination with the G3PA to.
Enable High-precision Temperature Contro.
Use cycle control to achieve power control with little noise.
Used in combination with the G3PA to connect to single- and,
three-phase loads GX-MD1618 Safety Precautions GX-MD1618
Three types of input method available: Internal adjuster,
external adjuster, or DC signals from 4 to 20 mA.
Streamline design. Both DIN track mounting and screw,
mounting possible.
Use linking terminals for close mounting of the G3PA.
Built-in isolation transformer.
Power supply range: 100 to 240 V. Isolation: Phototriac GX-MD1618 Safety Precautions.
Zero cross function: No.
Indicator: No.
Rated output load: 20 A at 100 to 240 VAC.
Rated input voltage(See note 1, 2.): 5VDC, 12VDC, 24VDC.
Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC. Both 100-V and,
200-V loads can be handled with the same model.
Dedicated, compact aluminum PCB and power elements used.
Built-in varistor effectively absorbs external surges GX-MD1618 Safety Precautions.
Quick-connect #110 input terminals and #250 output,
connections. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV) OMRON GX-MD1618 Manual. Cable with connector (1 to 2) /G79-I_-_-D1,
G79-O_-_-D1, G79-M_-_-D1.
Size: A, 750mm; B, 500mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable OMRON GX-MD1618 Manual. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 5 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 100 to 120 VAC.
Wide Lineup of General-purpose Solid State OMRON GX-MD1618 Manual.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch GX-MD1618 .
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Prrotective cover for greater safety GX-MD1618 Safety Precautions.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)).
Related products