E5EN-Q3H01T-W-FLK-N MANUAL OMRON E5EN-Q3H01T-W-FLK-N Communications Functions User's Manual
Product model: E5EN-Q3H01T-W-FLK-N
Name: Temperature Controller
Brand: OMRON
Sort: Communications Functions User's Manual
File language: English
Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 1 points OMRON E5EN-Q3H01T-W-FLK-N User's Manual.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance E5EN-Q3H01T-W-FLK-N
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance OMRON E5EN-Q3H01T-W-FLK-N User's Manual.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set OMRON E5EN-Q3H01T-W-FLK-N User's Manual.
It can be easily set by CS-Thermo (sold separately). Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: None.
Control output 1: Current output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relayss in the Temperature,
Controller using a Control Output ON/OFF Counter E5EN-Q3H01T-W-FLK-N MANUAL. E32-T81F-S type: resistant to environmental type; resistant to drugs,