E5EN-HAA2HBM-W-500 MANUAL OMRON E5EN-HAA2HBM-W-500 Communications Functions User's Manual
Product model: E5EN-HAA2HBM-W-500
Name: Temperature Controller
Brand: OMRON
Sort: Communications Functions User's Manual
File language: English
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use OMRON E5EN-HAA2HBM-W-500 User's Manual.
Event entry point: 2 E5EN-HAA2HBM-W-500
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV OMRON E5EN-HAA2HBM-W-500 User's Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. E3X-DA6RM-S amplifier unit
NPN outputThe main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V) OMRON E5EN-HAA2HBM-W-500 User's Manual.
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF countiing function, can prevent the maintenance of temperature controller internal relay E5EN-HAA2HBM-W-500 MANUAL. Simple and perfect optical fiber amplifier products,
High anti interference with optoelectronic IC Technology
Long sensing distance.
New phhotoelectric IC, enhanced anti interference E5EN-HAA2HBM-W-500 MANUAL.
Power supply reverse protection, output short circuit protection and output reverse connection protection.