Size: M12 (Brass); Single; Unshielded.
Sensing distance: 20 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Size: M8(Stainless steel)(See note 2.); Double; Shielded.
Sensing distance: 2 mm OMRON digital controller INSTRUCTION Manual.
Connecting method (See note 1.): M8 Connector (3-pin)
E5EC-QX2ASM-011
Body length: Long.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Control output 1: Voltage output.
Control output 2: --.
Auxiliary output: One.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation OMRON digital controller INSTRUCTION Manual.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other OMRON digital controller INSTRUCTION Manual. Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling E5EC-QX2ASM-011 INSTRUCTION Manual.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5EC-QX2ASM-011 INSTRUCTION Manual.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E5EC-QX2ASM-011 INSTRUCTION Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm),, interactive display PV/SV E5EC-QX2ASM-011 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation OMRON digital controller INSTRUCTION Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.