E3JM-DS70S4T detection method: diffuse reflection type,
Connection: terminal plate,
Detection range: 700mm.
Output status: ON into the light; light shading ON; switch conversion type.
Output: DC no contact. Function: timer,
2 types of cost reductionSize: 48 x 96mm.
Control output 1: linear current output OMRON E5CN-R2LU USER'S MANUAL.
Control output 2: voltage output (SSR driver).
Auxiliary output: 2 independent points
E5CN-R2LU
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible OMRON E5CN-R2LU USER'S MANUAL. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply OMRON E5CN-R2LU USER'S MANUAL.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. E3F3-R16 detection methods: Regression reflection type,
Lead extraction: CN M12,
Type: Plastic appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologySize: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5CN-R2LU MANUAL.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5CN-R2LU MANUAL.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.