LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> E5CN-R2H03L-FLK
E5CN-R2H03L-FLK MANUAL OMRON Temperature Controller E5CN-R2H03L-FLK USER'S MANUAL
Product model: E5CN-R2H03L-FLK
Name: Temperature Controller
Brand: OMRON
Sort: USER'S MANUAL
File language: English
Screw pitch: M6 (P=1.0).
Lead wire length: 4 m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON Temperature Controller USER'S MANUAL E5CN-R2H03L-FLK Sensing method: Through-beam.
Connection method: Pre-wired Connector (M8, 4 pins).
Sensing distance: 25 mm.
No. of opti- cal axes: 1.
Model: PNP output.
Photoelectric Sensor with Grooved.
Design and Easy Settings .
Groove-type Sensor with groove width of 25 mm OMRON Temperature Controller USER'S MANUAL.
Models are available with one or two light axes.
Models are available with M8 pre-wired connectors. E32-DC200F type: standard type; standard,
Specialty: M3 screw (small) with casing,
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsOntology: terminal type, analog input type OMRON Temperature Controller USER'S MANUAL.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5CN-R2H03L-FLK USER'S MANUAL.
Event input points: -.
Transfer output: output (using control output) E5CN-R2H03L-FLK USER'S MANUAL.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type E5CN-R2H03L-FLK USER'S MANUAL.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Control output: Relay output.
Auxiliary output: Two.
Communications: --.
Heater burnot: Detection for Single-phase heater.
Event inputs: One.
Power supply voltage: 100 to 240 VAC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance.
High-speed sampling aat 50 ms for applications with high-speed,
temperature increases E5CN-R2H03L-FLK MANUAL.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
commplete basic functions OMRON Temperature Controller USER'S MANUAL.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel.
Related products