E3T-SR14 INSTRUCTION sheet OMRON E3T-SR14 Manual
Product model: E3T-SR14
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Choose red, green light source of the 2 models.
Can detect a variety of colors.
Detection mode: diffuse reflection type.
Shape: horizontal.
Connection mode: lead wire.
Detection distance: green light 12mm positive and negative 2mm.
Output mode: open collector output type, NPN output.
Size: 48 x 48mm OMRON E3T-SR14 Manual.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V) E3T-SR14
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products OMRON E3T-SR14 Manual.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors OMRON E3T-SR14 Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultCase color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperrature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3T-SR14 INSTRUCTION sheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E3T-SR14 INSTRUCTION sheet.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Photoelectric Sensors
E3T-SL24
OMRON Photoelectric Sensors E3T-SL24
Sensing method: Convergent-reflective.
OMRON
Photoelectric Sensors
E3T-FT21
OMRON Photoelectric Sensors E3T-FT21
Sensing method: Through-eam Emitter
OMRON
Mounting Brackets
E39-S63
OMRON Mounting Brackets E39-S63
Slit width: 0.5-mm dia., 1 mm. Installa
OMRON
Photoelectric Sensors
E3T-FT13
OMRON Photoelectric Sensors E3T-FT13
Sensing method: Through-eam Emitter