LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> E3T-FT23-M1TJ
E3T-FT23-M1TJ Manual OMRON photoelectric sensors E3T-FT23-M1TJ INSTRUCTION sheet
Product model: E3T-FT23-M1TJ
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Control output: relay output.
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type OMRON photoelectric sensors INSTRUCTION sheet E3T-FT23-M1TJ
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating OMRON photoelectric sensors INSTRUCTION sheet.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8 OMRON photoelectric sensors INSTRUCTION sheet. 5mm). Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V) E3T-FT23-M1TJ INSTRUCTION sheet.
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver) E3T-FT23-M1TJ INSTRUCTION sheet.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E3T-FT23-M1TJ INSTRUCTION sheet.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), iinteractive display PV/SV E3T-FT23-M1TJ Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation OMRON photoelectric sensors INSTRUCTION sheet.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Photoelectric Sensors
E3T-FT21
OMRON Photoelectric Sensors E3T-FT21
Sensing method: Through-eam Emitter
OMRON
Photoelectric Sensors
E3T-FT13
OMRON Photoelectric Sensors E3T-FT13
Sensing method: Through-eam Emitter
OMRON
Photoelectric Sensors
E3T-FT22
OMRON Photoelectric Sensors E3T-FT22
Sensing method: Through-eam Emitter
OMRON
Photoelectric Sensors
E3T-FT24
OMRON Photoelectric Sensors E3T-FT24
Sensing method: Through-eam Emitter