LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> E3C-LDA21
E3C-LDA21 INSTRUCTION sheet OMRON E3C-LDA21 Manual
Product model: E3C-LDA21
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: 48 x 96mm.
Control output 1: linear current output.
Control output 2: voltage output (SSR driver).
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input OMRON E3C-LDA21 Manual.
Heating wire break, SSR fault detection function: 2 point (three phase heater) E3C-LDA21
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm OMRON E3C-LDA21 Manual.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications OMRON E3C-LDA21 Manual.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Control output: linear current output.
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter ccable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E3C-LDA21 INSTRUCTION sheet.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E3C-LDA21 INSTRUCTION sheet.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
Related products
OMRON
Photoelectric sensor
E3C-S20W
OMRON Photoelectric sensor E3C-S20W
Detection methods: the firing pattern. D
OMRON
Photoelectric sensor
E3C-DS10
OMRON Photoelectric sensor E3C-DS10
Detection mode: diffuse reflection type.
OMRON
Photoelectric sensor
E3C-2
OMRON Photoelectric sensor E3C-2
Detection methods: the firing pattern. D
OMRON
Small Spot/Mark
E3C-VS1G
OMRON Small Spot/Mark  E3C-VS1G
Sensing method: Reflective model for mar