LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> E2EQ-X7D1-M1J
E2EQ-X7D1-M1J INSTRUCTION sheet OMRON E2EQ-X7D1-M1J Manual
Product model: E2EQ-X7D1-M1J
Name: proximity switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use OMRON E2EQ-X7D1-M1J Manual.
Event input points: -.
Transfer output: -.
Communication: - E2EQ-X7D1-M1J
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV OMRON E2EQ-X7D1-M1J Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: M8(Stainless steel)(See note 2.); Single; Unshielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Long OMRON E2EQ-X7D1-M1J Manual.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications. The ultra small size, high performance and rich models.
5.5mm ultra small built-in amplifier.
Maximum detection distance 2.5mm. Workpiece shaking can also be stable detection.
Response frequency 1kHz.
Low consumption current.
Category: DC 3 wire type.
Shape: non shield.
Detection surface: above.
Detection range: 2.5mm.
Output form: PNP.
Action mode: NO. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of tthe thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E2EQ-X7D1-M1J INSTRUCTION sheet.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E2EQ-X7D1-M1J INSTRUCTION sheet.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
Related products
OMRON
Spatter-resistant Proximity Sensor
E2EQ-X3D1 2M
OMRON Spatter-resistant Proximity Sensor E2EQ-X3D1 2M
Appearance: Shielded, M12. Sensing dist
OMRON
Standard Proximity Sensor
E2E-X10D1-M1J-T-Z 0.3M
OMRON Standard Proximity Sensor E2E-X10D1-M1J-T-Z 0.3M
Appearance: M30. Sensing distance: 10 m
OMRON
Standard Proximity Sensor
E2E-X3D1-M1J-T-Z 0.3M
OMRON Standard Proximity Sensor E2E-X3D1-M1J-T-Z 0.3M
Appearance: M12. Sensing distance: 3 mm