Size: M12 (Brass); Double; Unshielded.
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Terminal type: Exposed-lead Models.
Protective tubing diameter D: 3.2 dia.
Protective tubing length L: 15cm OMRON E2EQ-X10Y1-1 Manual.
Lead wire type: Heat resistive.
Lead wire length M: 8m
E2EQ-X10Y1-1
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON E2EQ-X10Y1-1 Manual. Lead wire length: 1 m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON E2EQ-X10Y1-1 Manual. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN//STOP, alarm), interactive display PV/SV E2EQ-X10Y1-1 INSTRUCTION sheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E2EQ-X10Y1-1 INSTRUCTION sheet.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.