LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> E2EC-C3D1-M1TJ-1
E2EC-C3D1-M1TJ-1 INSTRUCTION sheet OMRON E2EC-C3D1-M1TJ-1 Manual
Product model: E2EC-C3D1-M1TJ-1
Name: proximity switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: M8(Stainless steel)(See note 2.); Double; Unshielded.
Sensing distance: 4 mm.
Connecting method (See note 1.): Pre-wired.
Body length: Long.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:-- OMRON E2EC-C3D1-M1TJ-1 Manual.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V E2EC-C3D1-M1TJ-1
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc OMRON E2EC-C3D1-M1TJ-1 Manual. .
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal OMRON E2EC-C3D1-M1TJ-1 Manual.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the processs of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E2EC-C3D1-M1TJ-1 INSTRUCTION sheet.
Through the infrared port can be carried out from the frront of the communication E2EC-C3D1-M1TJ-1 INSTRUCTION sheet.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.