Direction of Operation Key insertion: Horizontal.
Cable length: 5 m.
3NC (Slow-action).
Slim Safety Door Switches with IP67 Rating.
Slim design with a width of only 17 mm.
(three-contact models).
Reversible design allowing either front or rear mounting.
Built-in Switches with two- or three-terminal contact OMRON D4N-6287 Manual.
construction are available.
Operation Key with rubber mounting hole to absorb vibration and shock
D4N-6287
IP67 degree of protection. Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms OMRON D4N-6287 Manual.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) OMRON D4N-6287 Manual.
Certified standards: UL, EN (TÜV), and CCC. Type: Welding / wire type, with left column.
Driving rod: R type swing lever type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1c.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Drive rod: plunger type.
Built in switch structure: 1NC/1NO (speed type).
Economical safety limit switch.
The standard gold plated contacts ensure high reliability of the contact.
Can be used for standard load and small load. Release key type: Special release key.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+3NC.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monnitor contacts provide an,
array of monitoring patterns D4N-6287 INSTRUCTION sheet.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. D4N-6287 INSTRUCTION sheet.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.