D4N-5D32 Manual OMRON safety limit switch D4N-5D32 INSTRUCTION sheet
Product model: D4N-5D32
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ OMRON safety limit switch INSTRUCTION sheet.
Conduit size (See Note D4N-5D32): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available) OMRON safety limit switch INSTRUCTION sheet.
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors OMRON safety limit switch INSTRUCTION sheet. Actuator: One-way roller arm lever (horizontal).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now D4N-5D32 INSTRUCTION sheet.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4N-5D32 INSTRUCTION sheet.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC D4N-5D32 INSTRUCTION sheet. Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaaching the head D4N-5D32 Manual.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames OMRON safety limit switch INSTRUCTION sheet.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-4C32R
OMRON Pull-reset Safety Limit Switch D4N-4C32R
Actuator: Roller plunger. Conduit size:
OMRON
Safety Limit Switch
D4N-4A20
OMRON Safety Limit Switch D4N-4A20
Actuator: Roller lever resin lever, res
OMRON
Safety Limit Switch
D4N-6122
OMRON Safety Limit Switch D4N-6122
Actuator: Roller lever metal lever, res
OMRON
Safety Limit Switch
D4N-6131
OMRON Safety Limit Switch D4N-6131
Actuator: Plunger. Conduit size: 2-cond