C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT001-V1.
PCF.With the optical connector 1CPU Unit: CP1L-L CPU Units with 14 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Transistor output (sinking);
Inputs, 8; Output, 6 OMRON remote terminals UL Standards and CSA Standards
CRT1-OD16TA-1
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams OMRON remote terminals UL Standards and CSA Standards. C200HS-CPU33-E CPU
High-Performance CIM Version, Built-in RS-232C Port
The C200HS-CPU31-E and C200HS-CPU33-E controller offers the same basic functionality as the C200HS-CPU01-E/CPU03 controllers.
This CPU may be used ineither SYSMAC NET and/or SYSMAC LINK communication systems.
The built-in RS-232C port supports the same communications as the C200HS-CPU21/CPU23.Model : C500-PS222-E OMRON remote terminals UL Standards and CSA Standards.
Expansion I/O Backplane Power Supply
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 7 A, 5 VDC.Specification: Thermocouple input (K, J, L, T, R, S, B),
heater burnout alarm,
ON/OFF or advanced PID control,
manual operation,
transistor (PNP) output, 2 loops CRT1-OD16TA-1 UL Standards and CSA Standards. Unit classification: CJ1 Special I/O Units CRT1-OD16TA-1 UL Standards and CSA Standards.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Universal
inputs: Pt100 (3-wire), JPt100 (3-wire),
Pt1000 (3-wire), Pt100 (4-wire), K, J,
T, E, L, U, N, R, S, B, WRe5-26, PL II,
4 to 20 mA, 0 to 20 mA, 1 to 5V, 0 to 1 CRT1-OD16TA-1 UL Standards and CSA Standards. 25V,
0 to 5V, 0 to 10V, ±100 mV selectable range,
-1.25 to 1.25 V, -5 to 5 V, -10 to 10V,
±10V selectable range, potentiometer.
Conversion speed (resolution): Resolution
(conversion speed): 1/256,000 (conversion cycle:
60 ms/ 4 inputs) 1/64,000 (conversion cycle:
10 ms/4 inputs) 1/16,000 (conversion cycle:
5 ms/4 inputs).
Accuracy at ambient temperature of 25°C:
Standard accuracy: ±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.30A; 224V, -- CRT1-OD16TA-1 Manual.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) OMRON remote terminals UL Standards and CSA Standards.
All inputs are isolated.