CPU Q06CCPU-V-B Common Instructions 1/2 Manual MITSUBISHI Q06CCPU-V-B Programming Manual
Product model: Q06CCPU-V-B
Name: CPU
Brand: MITSUBISHI
Sort: Common Instructions 1/2 Programming Manual
File language: English
Input: 4 channels.
Platinum resistance (Pt100; JPt100).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost Q06CCPU-V-B Manual.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q06CCPU-V-B
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced Q06CCPU-V-B Manual.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode Q06CCPU-V-B Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected. 8 channels.
Platinum thermal resistance (Pt100, JPt100).
Nickel thermal resistance (Ni100) MITSUBISHI Q06CCPU-V-B Programming Manual .
Shedding detection function.
Conversion speed: 320ms/8 channel.
Inter channel isolation.
40 pin connector MITSUBISHI Q06CCPU-V-B Programming Manual .
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use MITSUBISHI Q06CCPU-V-B Programming Manual .
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery Q06CCPU-V-B Common Instructions 1/2.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and otther planned downtime,
The data is lost due to battery depletion Q06CCPU-V-B Manual.
The next time the power is turned on, the backup data will be automatically restored.
Related products
MITSUBISHI
C language CPU
Q06CCPU-V-H01
MITSUBISHI C language CPU Q06CCPU-V-H01
Input / output points: 4096 points. You
MITSUBISHI
C language CPU
Q06CCPU-V-B
MITSUBISHI C language CPU Q06CCPU-V-B
Input / output points: 4096 points. You
MITSUBISHI
C language CPU
Q06CCPU-V
MITSUBISHI C language CPU Q06CCPU-V
Input / output points: 4096 points. You