Unit classification: CJ1 Special I/O Units.
Product name: Position Control Units,
(High Speed type).
Specifications; Control method/Control,
output interface:Pulse-train line-driver,
output with Pulse Counter Function;
Number of control axes : 2 axes.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0 OMRON CP1W-40EDR Manual. 27A; 24V, --.
Standards: UC1, CE.
Motion Control Capabilities with Unit,
Synchronization and Even Higher Speed
CP1W-40EDR
Models are available with 2 or 4 axes,
and open-collector or line-driver outputs.
The CJ1W-NC214/NC414 have open-collector outputs,
and the CJ1W-NC234/NC434 have line-driver outputs.
Control 2 or 4 Axes High-speed, high-resolution,
position control is possible for servomotors ,
and pulse motors, and even linear motors,
and direct drive motors OMRON CP1W-40EDR Manual. Applicable CPU Units: CQM1H-CPU51/61.
Mounting locations/No. of Boards: One in Inner Board slot 2 (right slot).
Pulse inputs: 4 inputs.
Pulse outputs: 2 outputs.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 90 g max.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods OMRON CP1W-40EDR Manual.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space comparedd,
with previous systems CP1W-40EDR I/O Wiring Diagram.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1W-40EDR I/O Wiring Diagram.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.