LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> AnUCPU
AnUCPU Manual MITSUBISHI PLC AnUCPU AD57 control Instructions Programming Manual
Product model: AnUCPU
Name: PLC
Brand: MITSUBISHI
Sort: AD57 control Instructions Programming Manual
File language: English
Data format: RTU.
Data bits: 8.
A1SJ71UC24-R2-S2 and A1SJ71UC24-R4-S2 allow the Ans series PLC to be connected to the MODBUS network,
As the network from the station, and in accordance with the instructions of the main station of the CPU Ans user storage area for data reading / writing.
In addition to supporting the MODBUS protocol, these components also support the standard dedicated communication protocol for A1SJ71UC24 components MITSUBISHI PLC Programming Manual AnUCPU
This feature makes the main station of the data acquisition and control with more flexibility.
Support MODBUS slave station protocol.
Supports 1 to 21 function code.
Two transmission modes: RTU or ASCII. Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/ all points MITSUBISHI PLC Programming Manual.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
All points of independence.
38 point terminal station.
With the surge absorber.
CE certification.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal MITSUBISHI PLC Programming Manual AnUCPU Programming Manual.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc AnUCPU Programming Manual. .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process AnUCPU Programming Manual.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coiil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI PLC Programming Manual AnUCPU Manual .
Related products
MITSUBISHI
With Ethernet CPU
Q04UDEHCPU
MITSUBISHI With Ethernet CPU Q04UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
CPU unit
A2CJCPU
MITSUBISHI CPU unit A2CJCPU
Input points 512, CPU power supply, Item
MITSUBISHI
CPU unit
A1FXCPU
MITSUBISHI CPU unit A1FXCPU
Input and output points: 224 points. Inp
MITSUBISHI
CPU unit
A3NCPU
MITSUBISHI CPU unit A3NCPU
Input and output points: 2048 points. In