AY13EU Manual MITSUBISHI I/O Module AY13EU User's Manual
Product model: AY13EU
Name: I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
DC input points: 16 points.
Input voltage and current: 5mA, DC24V.
Response time: 10ms.
16 point /1 a public side.
Positive / negative sharing.
Output points: 16 points.
Output voltage and current: DC24V, 0.1A/1 point, 1.6A/1 common end.
Response time: 2ms.
16 point /1 a public side.
Output form: transistor output, leakage type MITSUBISHI I/O Module User's Manual.
40 pin connector.
Number of stations: 4 stops AY13EU
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system MITSUBISHI I/O Module User's Manual.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong MITSUBISHI I/O Module User's Manual.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness AY13EU User's Manual.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer AY13EU User's Manual. Optional features of memory card (Q/QnA/A/FX compatible).
4MB extended memory.
Applicable models: A985 (-V) /975/970/A960GOT (-B) /A956WGOT. Enter 16 points.
Voltage and current: 6/14mA DC12/24V.
Response time: 0.2ms.
16 point /1 public end, 20 point terminal.
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control requirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control program, to develop a design task book AY13EU User's Manual AY13EU Manual.
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devicees required for the determination of the system,
To determine the input / output device related to the MITSUBISHI PLC,
To determine the I/O PLC points MITSUBISHI I/O Module User's Manual.
Related products
MITSUBISHI
Relay output module
AY13
MITSUBISHI Relay output module AY13
Output points: 32 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY11A
MITSUBISHI Relay output module AY11A
Output points: 16 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY13E
MITSUBISHI Relay output module AY13E
Output points: 32 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY11AEU
MITSUBISHI Relay output module AY11AEU
Output points: 16 points. Voltage: DC24V