Interface: RS232C.
Transmission distance: 15 meters.
A1SJ71UC24-R2/R4/PR computer communication components can be relied on external intelligent devices such as computers and PLC for communication, the components are as follows:
Full / half duplex transmission,
4 special communication protocols,
No protocol and bidirectional mode,
Protocol selection switch function,
The optional baud rate, the highest 19 MITSUBISHI Programmable Controller Programming Manual
AD51H-BASIC 2K,
Since the echo diagnostic test. Multi axis positioning controller.
Program capacity: Max 60K step.
Input / output points: 1920 points.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI Programmable Controller Programming Manual. Output type: transistor output, source.
Output points: 16 points.
OFF leakage current: 0 MITSUBISHI Programmable Controller Programming Manual. 1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type AD51H-BASIC Programming Manual.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting AD51H-BASIC Programming Manual.
3 wire sensor input. Cable length: 15 meters.
For QCPU and GOT (need A9GT-QCNB) connection.
For the connection between GOT and GOT. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/6mA.
External connection: 3 wire AD51H-BASIC Programming Manual.
Spring clamping terminal platform push type input module.
Input module with diagnostic function
The use of push type, do not need screw fastening, so can reduce the wiring hours AD51H-BASIC Manual.
Can be used for each 1 points to enter the wiring of the broken wire detection.
Wiring abnormality of external power supply can be confiirmed MITSUBISHI Programmable Controller Programming Manual.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.