The A1SP60 pulse capture module is a 16 point DC24V input module,
Can be used as a general input module,
Can also be used as a pulse capture module,
Pulse capture function makes the input signal width in the sequence can be as short as 0.5ms,
Once there is a pulse signal input, the state is memory,
A1SP60 to ensure that the control process at least once again to control the state of the memory of the operation,
Input can be set to 4 blocks,
Each block can be set to a general function or pulse capture function MITSUBISHI touch screen User's Manual
A970GOT-TBA Output type: transistor drain.
Output points: 32 points.
Load voltage: DC5/12.
Load current: 0.016A.
Connection: FCN connector.
Common public end points: 32.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF MITSUBISHI touch screen User's Manual.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI touch screen User's Manual.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three A970GOT-TBA User's Manual. Close to input / output: 8 DC input or keyboard: 64 DC input, 16 transistor output.
Applicable model: A985/975/970/A960GOT (-B) A970GOT-TBA User's Manual. 32 point connector for welding (37 pin D-Sub connector).Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring A970GOT-TBA User's Manual.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module A970GOT-TBA Manual.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensorr input wiring MITSUBISHI touch screen User's Manual. A pack of 5.
Applicable models:
AJ65VBTS - - - type.
AJ65VBTCE - - - type.
AJ65VBTCU - - - type.
AJ65ABTP - - - type.
AJ65VBCU- - type.