A2SHCPU-S1 Manual MITSUBISHI A2SHCPU-S1 User's Manual
Product model: A2SHCPU-S1
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Input type: DC input, positive public end / negative public end.
Input points: 8 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC12V/AC240V/2A MITSUBISHI A2SHCPU-S1 User's Manual.
External connection: 2 line /2 line type A2SHCPU-S1
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. For A6TBXE/A6TBY36E/A6TBX54E/A6TBY54E/A6TBX70E (common cathode; source) long 2m.Input type: DC input, positive public end / negative public end.
Input points: 32 points MITSUBISHI A2SHCPU-S1 User's Manual.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 1 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program MITSUBISHI A2SHCPU-S1 User's Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Enter 64 points.
Above DC7V.
Response time: 16ms.
16 pin connector.
Output 64 points.
Response time: 16ms.
32 pin connector dynamic input and output data.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these standard electricall signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal A2SHCPU-S1 Manual .
So the standard telecommunication number, the conversiion between the number of operations to use a variety of computing A2SHCPU-S1 Manual .
This requires the resolution of the analog unit and the standard electrical signal.
Related products
MITSUBISHI
CPU unit
A1SCPU-S1
MITSUBISHI CPU unit A1SCPU-S1
Program memory capacity: 8k. Input / out
MITSUBISHI
CPU unit
A2ASCPU-S1
MITSUBISHI CPU unit A2ASCPU-S1
I/O points: 512. Processing speed: sec/
MITSUBISHI
Moving CPU unit
A73CPU-S1
MITSUBISHI Moving CPU unit A73CPU-S1
Multi axis positioning controller. Progr