LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> A273UHCPU 
A273UHCPU  Manual MITSUBISHI A273UHCPU  SV22(VIRTUAL MODE) Programming Manual
Product model: A273UHCPU 
Name: MOTION CONTROLLER
Brand: MITSUBISHI
Sort: SV22(VIRTUAL MODE) Programming Manual
File language: English
Axis of control: 2 axis linkage, 2 axis independence.
Interpolation function: 2 axis linear interpolation, 2 axis arc interpolation.
A1SD75 series components show the MITSUBISHI in the manufacture and design of CNC, frequency converter,
Integrated technical experience in servo system and PLC.
These components have a wealth of features that are sufficient to meet the highest requirements in the application of positioning control MITSUBISHI A273UHCPU  Programming Manual A273UHCPU 
Up to 3 axis linkage operation,
In low cost motion control applications, this component can be used to control the operation of a multi - to 3 axis, which can be used to account for only one slot. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1 MITSUBISHI A273UHCPU  Programming Manual. 5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 3 line /2 line type.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector MITSUBISHI A273UHCPU  Programming Manual.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. DC input points: 16 points.
Input voltage and current: 7mA, DC24V.
Response time: 10ms.
16 point /1 a public side.
Positive / negative sharing.
40 point terminal station.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simulaation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program A273UHCPU  Manual A273UHCPU  Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.