QD63P6 MITSUBISHI QD63P6 The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge


5 slots.
The main substrate needs to be equipped with CPU and power supply.
Requires 1 power modules.
Used to install large Q series modules.
Optimal network matching for application purposes and applications,
Seamless communication between different hierarchical systems.
Enhancing the ability of information communication through network QD63P6.
Thiis is also a major task in the field of automation.
Network environment provided by Q series
Is truly open & seamless.
Including based on universal ethernet,
Achieve easy management of the environment "IE Control CC-Link" controller network,
As well as in its management to achieve a high-speed, high-capacity transmission of the "IE Field CC-Link" field network QD63P6.
Also including Japan''s first, to achieve the world standard,
And get the SEMI certification of the field network "CC-Link",
And inherited the design concept of the provincial distribution network CC-Link/LT" QD63P6.
And support sensor networks "AnyWire",
To enrich the lineup flexibility to integrate the various layers of automation network MITSUBISHI QD63P6.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields MITSUBISHI QD63P6.
Can also be used in combination with the CPU module to achieve appropriate control.Input and output points: 1024 points MITSUBISHI QD63P6.
Input / output data points: 8192 points.
Program capacity: 60k.
Basic command processing speed (LD command) S:0.2.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The photoelectric coupler is composed of two luminous two extreme tubes and a photoelectric transistor.
Light emitting diode two: the input of a photo coupler and the change of electrical signal,
The light signal is generated by the light emitting diode, which is the same as the input signal.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light.
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal.
Photoelectric three levels: in the light of the light signal conduction, the degree of light signal and the intensity of the light signal.
The output signal has a linear relationship with the input signal in the linear operating region of the photoelectric coupler.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Input: 6 channels.
200/100/10kpps.
Counter input signal: 5VDC.
40 pin connector.
Support high resolution devices. Pulse input and high speed counter module product group satisfying high speed and high precision control application.
High speed counter module for counting high-speed pulse train.
Can be used in combination with the external encoder for positioning and other control.
The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge.
Each 1 channel is equipped with 2 points of external uniform output.
Can be selected according to the use of "consistent output function", "continuous comparison function", to achieve high-speed control of external equipment. (QD64D2)
Provides a variety of functions, such as the same output test function (using a continuous comparison function), the default function, the latch counter function,
In order to meet the needs of various applications. (QD64D2)
The maximum count rate of the input pulse can be up to 8Mpps (differeential input, 2 phase, 4 double frequency) QD63P6.
Can be in the semiconductor, liquid crystal manufacturing and other high position accuracy requirements of the equipment,
Perform accurate position tracking using high resolution encoders. (QD65PD2)