Unit type: CS1 Basic I/O Units.
Product name: Interrupt Input Unit.
Specifications: I/O points,
16 inputs; Input voltage, 24 VDC;
Input current, 7 mA; Input pulse width,
ON time, 0.1 ms max, OFF time,
0.5 ms max; External connection,
Remov able terminal block C500-OC221-E.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansionn I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No C500-OC221-E.
Words required: 1 word.
Current consumption: 5V system, 0.10A;
26 V system, --.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. CV500-MP SYSMAC BUS PC Unit PC Card Interface Board For PCMCIA 2 C500-OC221-E.1 Type I and II cards CV500-MP602.
Product name: E@@S type CPU Units with 10 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 6; Outputs, 4;
Output type: Transistor (sinking).
Program capacity: 2K steps.
memory Data capacity: 2K words OMRON C500-OC221-E.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.11A; 24 V,--.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality OMRON C500-OC221-E.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Model : C500-LK201-V1.
RS-232C/RS-422.I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 60K steps.
Data memory capacity: 128K words (DM: 32K words, EM: 32K words ×3 banks)A memory card suitable for Phoenix PCM+3 OMRON C500-OC221-E.2 and one of thefollowing Bus Connection Units is required. No PC card is provided with the Unit.C200H CPU 100/200-240VAC C200H-CPU02-E.Power supply: DC power supply.
Output method: Relay output.
Inputs points: 12 points.
Outputs points: 8 points.Name: Screw Terminal Block with SSR Outputs.
Specifications: Outputs;
8 outputs; SSR.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site C500-OC221-E.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.