LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
FR-F840-02600-2-60 MITSUBISHI FR-F840-02600-2-60


Input points: 4 points.
Weight: 0.02kg.
Function expansion board is used in the FX3SA, FX3S, FX3GA, FX3G, FX3GE on the small number of input and output extension of the product,
Can be built into PLC. CC-Link interface module.
PLC FX can be used as the CC-LINK remote device station connection FR-F840-02600-2-60.
If using CC-LINK type FX2N-16CCL-M systemm master module,
So just PLC CC-LINK can build FX system.
MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 110kw FR-F840-02600-2-60.
SLD converter rated current: 260A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup FR-F840-02600-2-60.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor MITSUBISHI FR-F840-02600-2-60.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor) MITSUBISHI FR-F840-02600-2-60.
Other manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving. MITSUBISHI inverter FR-D720S series MITSUBISHI FR-F840-02600-2-60.
Voltage level: single phase 200V.
Frequency converter capacity: 0.2KW.
VVVF frequency control, vector control frequency conversion, direct torque control is a kind of AC - DC - AC frequency conversion.
The common drawback is that the input power factor is low, the harmonic current is big, and the DC circuit needs large energy storage capacity,
Renewable energy and can not be fed back to the power grid, which can not be carried out in the four quadrant operation. To this end, the matrix type of AC - AC variable frequency arises at the historic moment.
Because the matrix type alternating current frequency saves the intermediate DC link, thereby, the electrolytic capacitor with large volume and high price can be omitted.
It can achieve a power factor of L, the input current is sinusoidal and can run in four quadrant, the power density of the sysstem is large FR-F840-02600-2-60.
Although the technology is not yet mature, but still attract a large number of scholars in-depth study.
In fact, the quality is not the indirect control current, flux, but the torque is directly used as the control to achieve.

Related supply information