Name: SYSMAC LINK Fiber-optic Power Supply.
Model: C200H-APS01.Supply voltage: 24 VDC
Operating voltage range: 20.4 to 28.8 VDC
Power consumption: 100 W max.
Output capacity: 12 A, 5 VDC
Communi-cations cable: 100Base-TX.
CJ1W-ETN11 Ethernet Communications services: FINS communications, FTP server, socket services, and mail services CJ1W-ETN11.
Unnit numbers: 0 to F (4 Units max.).Name: PID Control Module.
Model: C200H-PID03.
Output: Current output.Unit type: CJ1 Basic I/O Units CJ1W-ETN11.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 64 outputs;
Maximum switching capacity, 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, Fujitsu connector.
No. of words allocated: 4 words.
Current consumption: 5V, 0 CJ1W-ETN11.17A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices OMRON CJ1W-ETN11.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality OMRON CJ1W-ETN11.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Model: CPM2C-8ER. Units with relay outputs only.
I/O terminal block.
Outputs: 8 outputs OMRON CJ1W-ETN11.
Input type: 24 VDC.
Output type: relay.C500-ID Special I/O Unit ID Sensor Unit Long-distance C500-IDS22.Name: SYSMAC LINK Module.
Model: C200HW-SLK14.
Communications method: N: N token bus.
Transmission method: Manchester code, base band.
Transmission path: Daisy chain.
Weight: 500g max.Model: C200HW-COM02-V1.
Specifications: One RS-232C port.Connection type: Screw - HPCF connector.
Description: Controller link repeater unit (wire to HPCF fibre).Name: MIL Connector Type.
Specifications: Analog inputs; 4 inputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site CJ1W-ETN11.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.