Model: CPM2C-20C1DT1C-D. CPU Unit: Units with 20 I/O points.
2 Fujitsu connectors.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.
Internal clock: Yes.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units CJ1W-B7A04.
points Input: 8 inputs.
Signaal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block CJ1W-B7A04.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value CJ1W-B7A04.
Because of this, no ladder program is required,
at the CPU Unit for scaling OMRON CJ1W-B7A04.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems OMRON CJ1W-B7A04.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems OMRON CJ1W-B7A04.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 outputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used iin the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications CJ1W-B7A04.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
 